Once the D-Channel card is enables we
can try to establish the link.
In LD 60 we can use the ENLL <Loop
Number> to bring the LOOP into
service. This needs to be done on both
systems i.e. both ends of the link before
the service will correctly establish.
If necessary the LOOP can be disabled
using the DISL <Loop Number>
command and the counters listed LCNT
and reset RCNT before re-enabling the
LOOP to clear any issues.