As we have a High Availability system
we need to check that the system is
synchronising correctly between the two
cores.
To check the status use the > STAT
CPU command in LD 135 . What we
should see is a REDUNDANT Status for
both the SYSTEM and DISK. This
means that both the memory and the
disk (FMD) have successfully
synchronised allowing us to swap
service from one core to the other.
There is also a test which can be run
from LS 137
>TEST RDUN
Be patient as the test can take over a
minute to run.
To swap the Active and Standby Call
servers over we can use the command
in LD 135
> SCPU