Getting the correct time setup across all
devices in the system can be difficult
with the CS1K so the following can help
LD 2 TTAD & STAD to print and set time
for SA and HA ( VxWorks Call Servers)
To set the NTP for a VxWorks call
server:-
In LD 117
ENL/DIS NTP
Enable or Disable NTP
CHG NTP IPADDR 10.10.10.202
Change IP Address of NTP Server
STAT NTP
Check setup of NTP for Call Server
SYNC NTP MANUAL or
BACKGROUND
Execute NTP Sync now or overnight
You may also need to adjust the UTC
offset for the call server.
CHG UTCOFFSET <+/-hh:mm>
Changes UTC offset by specified
amount
CS 1000 Rel 7.5 16/04/2013
Copyright Amlex Associates Ltd